NEW EXAM INTERNATIONAL CODE COUNCIL FIRE-INSPECTOR-II BRAINDUMPS, EXAM FIRE-INSPECTOR-II DETAILS

New Exam International Code Council Fire-Inspector-II Braindumps, Exam Fire-Inspector-II Details

New Exam International Code Council Fire-Inspector-II Braindumps, Exam Fire-Inspector-II Details

Blog Article

Tags: New Exam Fire-Inspector-II Braindumps, Exam Fire-Inspector-II Details, Fire-Inspector-II Pass Leader Dumps, Latest Fire-Inspector-II Exam Simulator, Fire-Inspector-II Exam Actual Questions

Maybe you want to get the Fire-Inspector-II certification, but daily work and long-time traffic make you busier to improve yourself. Thanks to our Fire-Inspector-II training materials, you can learn for your certification anytime, everywhere. If you get our products, you will surely find a better self. As we all know, the best way to gain confidence is to do something successfully. With our Fire-Inspector-II Study Guide, you will easily pass the Fire-Inspector-II examination and gain more confidence.

It is universally accepted that the competition in the labor market has become more and more competitive in the past years. In order to gain some competitive advantages, a growing number of people have tried their best to pass the Fire-Inspector-II exam. Because a lot of people hope to get the certification by the related exam, now many leaders of companies prefer to the candidates who have the Fire-Inspector-II Certification. In their opinions, the certification is a best reflection of the candidates’ work ability, so more and more leaders of companies start to pay more attention to the Fire-Inspector-II certification of these candidates.

>> New Exam International Code Council Fire-Inspector-II Braindumps <<

High Pass-Rate New Exam Fire-Inspector-II Braindumps, Exam Fire-Inspector-II Details

Our Fire-Inspector-II learning materials not only provide you with information, but also for you to develop the most suitable for your learning schedule, this is tailor-made for you, according to the timetable to study and review. I believe you can improve efficiency. Our Fire-Inspector-II exam prep will give you a complete after-sales experience. You can consult online no matter what problems you encounter. You can get help anywhere, anytime in our Fire-Inspector-II test material. Fire-Inspector-II test questions have very high quality services in addition to their high quality and efficiency.

International Code Council 67 - Fire Inspector II Exam Sample Questions (Q16-Q21):

NEW QUESTION # 16
The maximum quantity of liquefied petroleum gas (LP-gas) in containers stored by a dealer awaiting resale, and are at one location in a building that is not accessible to the public, is __ lb. water capacity.

  • A. 1,000
  • B. 2,000
  • C. 2,500
  • D. 0

Answer: B

Explanation:
The storage of liquefied petroleum gas (LP-gas) in containers by dealers awaiting resale is regulated by the
2021 International Fire Code (IFC), Section 6109 - Storage of Portable LP-Gas Containers.
IFC 6109.11 - Storage Within Buildings Not Accessible to the Public:
"Storage of LP-gas containers in buildings that are not accessible to the public shall be limited to a maximum aggregate quantity of 2,000 pounds water capacity at one location." Why Other Options Are Incorrect?
A: 735 lb. - Too low; the maximum allowed is 2,000 lb.
B: 1,000 lb. - Incorrect; IFC allows up to 2,000 lb.
D: 2,500 lb. - Exceeds the 2,000 lb. maximum permitted storage quantity.


NEW QUESTION # 17
A 501 gal. water capacity above-ground liquefied petroleum gas (LP-gas) tank located 20 ft. from a 250 gal.
LP-gas tank must be separated a minimum of __ ft. from adjoining property.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: B

Explanation:
Reference to LP-Gas Tank Separation Requirements:
The International Fire Code (IFC 2021), Table 6104.3, provides minimum separation distances for above- ground LP-gas tanks based on capacity and proximity to each other or property lines.
According to Table 6104.3, for an LP-gas tank with a 501-gallon capacity located near a 250-gallon tank, the required minimum separation distance from adjoining property is 10 feet.
Why Separation Distance is Important:
LP-gas is highly flammable, and inadequate separation distances increase the risk of fire spread and explosion hazards.
Proper spacing ensures safety for occupants, emergency responders, and nearby properties.
Clarification of Incorrect Answer Choices:
A: 5 ft. # Incorrect
Too close per IFC 6104.3; does not meet safety requirements.
C: 20 ft. # Incorrect
20 feet is required for larger tanks, but not for the combined 501-gal. and 250-gal. tank setup.
D: 25 ft. # Incorrect
Greater than the required minimum; while more distance is safer, IFC mandates a minimum of 10 feet.
Conclusion:
The correct and verified answer is B (10 feet) based on IFC 6104.3, ensuring safe LP-gas tank separation from adjoining properties.


NEW QUESTION # 18
One or more approved fire extinguishers must be located within __ ft. of hot work locations.

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: A

Explanation:
Fire Extinguisher Requirements for Hot Work Locations
According to the International Fire Code (IFC) 2021, Section 3504.2.6, one or more approved fire extinguishers must be located within 30 feet of hot work locations.
Hot work includes welding, cutting, grinding, brazing, or any operation that generates heat, sparks, or flames.
2. Why 30 Feet is the Correct Answer
Hot work presents a high fire risk, and quick access to fire extinguishers is crucial for immediate response.
The 30-foot requirement ensures that extinguishers are readily accessible without obstructing the work area.
3. Verification of Other Options
Option A (20 feet) - Incorrect, as the IFC mandates a 30-foot minimum distance.
Option C (40 feet) - Incorrect, as this exceeds the maximum distance allowed under the fire code.
Option D (50 feet) - Incorrect, as fire extinguishers must be closer to provide effective fire suppression.
Reference Sources:
International Fire Code (IFC) 2021 - Section 3504.2.6 (Fire Extinguishers for Hot Work) NFPA 51B: Standard for Fire Prevention During Welding, Cutting, and Other Hot Work ICC Fire Inspector II Study Guide (2021) Thus, the correct and verified answer is: B. 30 feet. #


NEW QUESTION # 19
The use of listed portable unvented oil-burning heating appliances is prohibited in which of the following occupancies?

  • A. Groups A, E, I, R-1, R-2, R-3, and R-4 occupancies
  • B. Groups A and B occupancies
  • C. Groups R-3, M, S-1, and S-2 occupancies
  • D. Groups B and F occupancies

Answer: A

Explanation:
Restrictions on Portable Unvented Oil-Burning Heaters
According to the International Fire Code (IFC) 2021, Section 603.4, the use of listed portable unvented oil- burning heating appliances is prohibited in certain occupancies where fire and life safety risks are higher.
The prohibited occupancies include:
Group A (Assembly) - Includes theaters, churches, stadiums, etc.
Group E (Educational) - Includes schools, daycares, etc.
Group I (Institutional) - Includes hospitals, nursing homes, jails, etc.
Group R-1, R-2, R-3, R-4 (Residential Occupancies) - Includes hotels, apartments, assisted living, and residential care facilities.
2. Why These Occupancies Are Prohibited
Portable unvented oil-burning heaters pose a significant fire hazard and can produce harmful gases such as carbon monoxide.
In high-occupancy and residential buildings, improper use or malfunction of these heaters could lead to fatal fire or health hazards.
Ventilation concerns in institutional and assembly settings make these heaters particularly dangerous.
3. Verification of Other Options
Option A (Groups A and B occupancies) - Incorrect, as Group B (Business) is not explicitly prohibited from using these heaters.
Option B (Groups B and F occupancies) - Incorrect, as Group F (Factory/Industrial) is not listed under IFC
603.4 as a prohibited occupancy.
Option C (Groups R-3, M, S-1, and S-2 occupancies) - Incorrect, as M (Mercantile) and S (Storage) occupancies are not listed as restricted areas.
Reference Sources:
International Fire Code (IFC) 2021 - Section 603.4 (Portable Unvented Oil-Burning Heating Appliances) NFPA 1: Fire Code (Portable Heater Use Restrictions in Various Occupancies)


NEW QUESTION # 20
Flammable medical gas supply cylinders located inside of a building must be stored in a separate room of not less than __ fire-resistive construction when exceeding 200 cu. ft.

  • A. 1-hour
  • B. 3-hour
  • C. 2-hour
  • D. 1/2-hour

Answer: C

Explanation:
The storage of flammable medical gas supply cylinders inside a building is regulated by 2021 International Fire Code (IFC) Section 5306 - Medical Gas Systems.
IFC Section 5306.2.1 - Storage of More Than 200 Cubic Feet of Medical Gases:
When the quantity of flammable medical gas exceeds 200 cubic feet, it must be stored in a separate room with a minimum 2-hour fire-resistance rating.
The room must also comply with ventilation and explosion control requirements per NFPA 99 (Healthcare Facilities Code).
Why Other Options Are Incorrect?
A: 1/2-hour - Insufficient fire resistance for high-risk gas storage.
B: 1-hour - Does not meet the minimum 2-hour requirement set by the IFC.
D: 3-hour - Exceeds the minimum required by code; the correct requirement is 2-hour fire-resistive construction.


NEW QUESTION # 21
......

The 67 - Fire Inspector II Exam (Fire-Inspector-II) web-based practice questions carry the above-mentioned notable features of the desktop-based software. This version of ActualPDF's 67 - Fire Inspector II Exam (Fire-Inspector-II) practice questions works on Mac, Linux, Android, iOS, and Windows. Our customer does not need troubling plugins or software installations to attempt the web-based International Code Council in Fire-Inspector-II Practice Questions. Another benefit is that our International Code Council Fire-Inspector-II online mock test can be taken via all browsers, including Chrome, MS Edge, Internet Explorer, Safari, Opera, and Firefox.

Exam Fire-Inspector-II Details: https://www.actualpdf.com/Fire-Inspector-II_exam-dumps.html

International Code Council New Exam Fire-Inspector-II Braindumps DumpStep : less questions with resonable price, and we promise that almost all the test points would be found from our products, Since our practice test materials are compiled by the top International Code Council experts around the world, the contents in the Fire-Inspector-II training materials are definitely quintessence for the exam, which covers all of the key points as well as the latest information about the events happened in the field recently, International Code Council New Exam Fire-Inspector-II Braindumps These values guide every decision we make, everywhere we make them.

A day does not go by without someone in the business media waxing Fire-Inspector-II eloquent about the pace of change, the increasing turbulence of technology, or the massive pressures of global competition.

100% Pass Quiz International Code Council - Fire-Inspector-II Accurate New Exam Braindumps

Test day preparations will fit into your normal New Exam Fire-Inspector-II Braindumps routine of getting ready to study or practice for an upcoming certification exam,DumpStep : less questions with resonable price, New Exam Fire-Inspector-II Braindumps and we promise that almost all the test points would be found from our products.

Since our practice test materials are compiled by the top International Code Council experts around the world, the contents in the Fire-Inspector-II Training Materials are definitely quintessence for the exam, which covers all New Exam Fire-Inspector-II Braindumps of the key points as well as the latest information about the events happened in the field recently.

These values guide every decision we make, New Exam Fire-Inspector-II Braindumps everywhere we make them, Generally speaking, customers who study hard enough tomake preparations for IT exams can, after Exam Fire-Inspector-II Details 20 or 30 hours of practice, take part in the exam and pass exams for certificates.

The new update information of 67 - Fire Inspector II Exam testking PDF will be sent New Exam Fire-Inspector-II Braindumps to you as soon as possible, so you do not need to bury yourself in piles of review books or get lost in a great number of choices.

Report this page